Configuration variables for analog motor version 5-9: CV1 Primary Adress CV2 Vstart 0-255 CV3 Acceleration Rate 0-255 CV4 Deceleration Rate 0-255 CV5 Vmax 0-255 CV6 Vmid 0-127 neg. 128-255 pos. CV17 Extended Adress Low Byte CV18 Extended Adress High Byte CV19 Consist Adress CV29 0=DIR 1=14/28 2=PWRSRC 3=ADVACK 4=SPDTAB 5=LADRE 6= 7=ACCDEC (see below) CV49 Output F1-F8 to GP2 Bit 76543210 = F87654321 CV50 Output F1-F8 to GP4 CV51 Output F1-F8 to GP5 CV55 2. Vmax switchable over F1-F8 or over drive direction CV64 configuration byte (see below) -------------------------------- DIRINV CV29,0 direction inverted (+light) FS28 CV29,1 14/28 speed step LIINV CV29,2 light inverted (PWRSRC never used) STAB CV29,4 speedtab / CV2,CV5&CV6 LADRE CV29,5 long adress enable ACKOFF CV29,6 acknowledge off for piggy bag decoder, don't use this bit -------------------------------- FLOFF CV64,0 front light switch with cv50 (GP4) RANGIER CV64,0 low activ, mapped with FLOFF BLOFF CV64,1 back light switch with cv51 (GP5) SPEED2 CV64,1 low activ, mapped with BLOFF RDLTON CV64,2 red light on (back light) BRKON CV64,3 brake light on HI2LOFS CV64,4 reserved FLACKON CV64,5 flacker on LITAUTO CV64,6 firebox open/close automatically cv55 same as cv5, activate over cv64,1=0, normal on, and switchable over cv51 is cv55=0 then the 2nd Vmax is deactivated. is cv51=0 then the 2nd Vmax is for direction use. if bit cv29,0=0 then cv5 controls forward direction and cv55 controls reverse direction. for example: is cv64,0=0, cv64,1=0 cv50,1=1 and cv51,1=1 then F2 switches the light on both sides on and activate the 2nd Vmax over cv55.